Compactness and size have always been criteria in detriment to performance for helium leak and hydrogen detecting. Turbo Vacuum provides economical and user friendly units in a small package, great for detecting light traces of gas which are capable of infiltrating a micro opening the size of 5 x 10-12 mbar. They are portable, highly sensitive, upgradeable for use on large vacuum systems, and have analog/digital inputs and outputs for demanding industries such as: Semiconductor, Medical, Pharmaceutical, Electronics, Instrumentation, and Aeronautics. Other advantages include: Simple operation, ISO9001 compatible, Vacuum and sniffing operation, Removable operating unit, Leak rate as a numerical and bar graph display, Optimum suppression of background signal, Short recovery time, Rapid results due to high inlet pressure and high helium pumping speed, and color touchscreen displays.
Features
• Self Automated
• No contamination
• Start Stop operation
• Modular design with adaptable pumping capacity
• Easy integration into any vacuum system
• Color touchscreen display
• Battery operated
HLD-ASM310

ASM310

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
1 x 10-7
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
2
Response Time (seconds):
< 1
Inlet Pressure Max (mbar):
15
Roughing Pump (Flow Rate CFM):
Dry / 1
System Voltage:
100-240V
Price:
$26,860.00

Quardo_leak_detector

QUADRO

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
1 x 10-7
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
2
Response Time (seconds):
< 1
Inlet Pressure Max (mbar):
15
Roughing Pump (Flow Rate CFM):
Wet / 1.5
System Voltage:
100-240V
Price:
$23,490.00

Quardo_leak_detector

QUADRO DRY

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
1 x 10-7
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
2
Response Time (seconds):
< 1
Inlet Pressure Max (mbar):
15
Roughing Pump (Flow Rate CFM):
Dry / 1.8
System Voltage:
110-240V
Price:
$23,692.00

Vario

VARIO

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
1 x 10-7
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
2
Response Time (seconds):
< 1
Inlet Pressure Max (mbar):
15
Roughing Pump (Flow Rate CFM):
None
System Voltage:
110-240V
Price:
$22,680.00

HLD-ASM340

ASM340

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
1 x 10-7
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
3
Response Time (seconds):
< 1
Inlet Pressure Max (mbar):
10
Roughing Pump (Flow Rate CFM):
Wet / 9
System Voltage:
110-240V
Price:
$23,800.00

HLD-ASM340

ASM340D

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
5 x 10-3
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
3
Response Time (seconds):
0.5
Inlet Pressure Max (mbar):
18
Roughing Pump (Flow Rate CFM):
Dry / 2
System Voltage:
110-240V
Price:
$25,100.00

HLD-VSPR021

VSPD021

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
5 x 10-3
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
3
Response Time (seconds):
0.5
Inlet Pressure Max (mbar):
13
Roughing Pump (Flow Rate CFM):
Oil Seal / 5
System Voltage:
110-240V
Price:
$22,186.00

HLD-VSPR021

VSPD031

Technical Specifications

Inlet Flange:
NW 25
Smallest Detectable Leak Rate (mbar):
5 x 10-12
Sniffen Probe, Detectable Leak Rate:
5 x 10-3
Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
3
Response Time (seconds):
0.5
Inlet Pressure Max (mbar):
13
Roughing Pump (Flow Rate CFM):
Dry / 3
System Voltage:
110-240V
Price:
$24,431.00

KYKY_ZJ-2300

ZJ-2300

Technical Specifications

Inlet Flange:
NW 25, ISO-KF
Smallest Detectable Leak Rate (mbar):
2.0 x 10-11
Sniffen Probe, Detectable Leak Rate:

Detectable Gases:
HE4, HE3, H2
Cold Start To Ready (minutes):
7
Response Time (seconds):
< 2
Inlet Pressure Max (mbar):
1000 Pa
Roughing Pump (Flow Rate CFM):
Wet –
System Voltage:
110-240V
Price:
$21,400.00